Cooling Towers

Cooling Tower Service & Repair in Austin, TX


Cooling towers are the most neglected equipment in most central plants and the fastest way to wreck chiller efficiency. We service, rebuild and replace towers across Central Texas.

Why Towers Matter

The cheapest efficiency you are probably leaving on the roof


Everything a water-cooled chiller does depends on the tower rejecting heat properly. When fill scales up, drift eliminators clog, or a gearbox starts to fail, condenser water temperature climbs and the chiller has to work harder for the same tonnage. That shows up as higher approach temperatures, higher energy cost, and eventually as high-head faults that get blamed on the chiller.

Central Texas water chemistry is hard on towers. Scale, biological growth and airborne debris all accumulate quickly here, and a tower that gets cleaned once every few years is costing you money continuously in the meantime. Consistent tower maintenance is one of the highest-return items in a commercial mechanical budget.

We service open and closed circuit towers, and we look at them as part of the condenser water system rather than in isolation — pumps, strainers, piping, valves, water treatment and controls together with the tower itself. See chiller service for the other half of the loop.

Tower Services

What we handle


  • Full tower cleaning, basin flush and disinfection
  • Fill replacement and drift eliminator replacement
  • Gearbox service, oil changes and replacement
  • Drive shaft, coupling and belt service
  • Fan blade inspection, balancing and replacement
  • Motor replacement and VFD troubleshooting
  • Basin repair, sealing and protective coating
  • Float valves, make-up water and overflow
  • Sump screens, strainers and suction basins
  • Condenser water pump repair and alignment
  • Water treatment system coordination and testing
  • Full tower replacement and rigging
Water Safety

Legionella risk and why tower hygiene is not optional


Cooling towers are a recognised amplification site for Legionella bacteria, which is why tower hygiene is a life-safety issue and not just a maintenance preference. Warm water, biofilm and aerosol drift are the conditions towers create by design, and neglected towers create them very well.

Facilities in healthcare, senior living, hospitality and higher education frequently operate under a water management plan, and many insurers and accrediting bodies now expect documented tower cleaning and treatment records. We perform cleaning and disinfection, coordinate with your water treatment provider, and document the work so it stands up in an audit.

If your building does not currently have a written water management plan and you operate a tower, that is worth addressing regardless of who does your mechanical work.

Where We Work

Serving the Austin metro and Central Texas


Cooling tower and condenser water service for central plants across Austin, Round Rock, Cedar Park, Georgetown and the wider Central Texas region.

Questions

Frequently asked questions


How often should a cooling tower be cleaned?

Most Central Texas facilities should plan on a full cleaning at least twice a year, with inspections quarterly. Our combination of heat, long cooling season, hard water and airborne debris fouls towers faster than in milder climates. Facilities with a formal water management plan — healthcare, senior living, large hospitality — often clean more frequently and document each event.

How do I know if my tower is hurting chiller performance?

The clearest indicator is condenser water approach temperature trending upward over time. Rising head pressure, chiller high-pressure trips on hot afternoons, and energy cost climbing without a corresponding change in load all point the same direction. If nobody is logging tower performance, that is itself worth fixing — you cannot see drift you are not measuring.

Can a tower be rebuilt instead of replaced?

Often, yes. Fill, drift eliminators, gearboxes, motors, fans and basin coatings are all serviceable items, and a structurally sound tower with a corroded basin or degraded fill is usually a rebuild rather than a replacement. Where the structure itself has failed, or the tower is badly undersized for the current load, replacement is the better spend. We will give you the comparison in writing.

Request Service or a Quote

Let's get your building running right


Tell us what is going on and we will get a technician or an estimator on it. For anything urgent, call — that is always the fastest path.

Request service or a quote

Urgent? Call (512) 316-9646 — someone answers 24/7.

Equipment down right now?

Emergency commercial HVAC and chiller response across Austin and Central Texas — nights, weekends and holidays.

Call Now Request Quote